PA - SAMPLING VALVE

Representative and safe sampling of pure and slightly solids-laden media in the chemical, pharmaceutical and other industries. The Richter series PA/F (fluoroplastic lining PFA) and PA/S (stainless steel version) are specially suitable for taking samples.

Features

Sample always representative: sampling from the main flow

No falsification of the sample through residual media: design cavity-free

High safety through PFA lining and bellows seal

Representative sampling

Specifications

  • Design:

    ISO/DIN

  • Nominal Pressure:

    16 bar

  • Lining:

    PFA

  • Housing Material:

    EN-JS 1049 / 1.4435

  • Face-to-Face:

    DIN EN 558-1 and ISO 5752 series 1

  • Flanges to:

    ISO 7005-2, type B or flanges drilled to ASME B16.5 class 150, raised face

  • Temperature Range:

    -60 °C to +200 °C (-75 °F to +400 °F)

  • Certifications:

    EU Pressure Equipment Directive 2014/68/EU, German Clean Air Act (TA-Luft)